Panel Meters
Panel meters are applicable to measure various power parameters like voltage, current, frequency. This has vide application area like control panels, testing instrument, machinery, etc. GELCO has also developed a hour meter to make a complete range of panel meters.
 
Micro controller based technology. (Hour meter)
Easy to install
Available in DIN size enclosure.
VI-48/96
Voltage Meter
AI-48/96
Current Meter
FI-96
Frequency Meter
Supply 230V AC 20%, 50 Hz 230V AC 20%, 50 Hz 230V AC 20%, 50 Hz
Display Parameter Voltage Ampere Frequency
Range 0 - 750 V (AC) 0 - 20 A (AC) 0-50.0 Hz
Display 0.56" Seven Segment LTD 0.56" Seven Segment LTD 0.56" Seven Segment LTD
Dimension VI-48 / AI-48     VI-96 / AI-96   FI-96
Size(mm) 48 x96     96x96   96x96
Cut Out(mm) 44x92     92x92   92x92
Depth(mm) 78     65   65
Weight(Gms) Approx. 320     500   265
Selection Method - - -
Reset - - -
Operating Temperature 0oC to 50oC 0oC to 50oC 0oC to 50oC
 
 
AVI-48/96
Volt & Current Meter
AVM-96
Volt & Current Meter
DHM-5701
Hour Meter
Supply 230V AC 20%, 50 Hz 230V AC 20%, 50 Hz 110/230/415V AC, 50Hz
Display Parameter Voltage & Ampere Voltage & Ampere Time (Hour)
Range 0-20A & 0 - 550V (AC) 0-700A & 0-550V
External CT required Beyond 5Amp.
0-99999.9 Hour
Display 0.56" Seven Segment LED 0.56" Seven Segment LED 0.4" Seven Segment LTD
Dimension AVI-48     AVI-96 AVM-96 DHM-5701
Size(mm) 48x96     96x96 96x96 38x63
Cut Out(mm) 44x92     92x92 92x92 29x53
Depth(mm) 78     65 65 85
Weight(Gms) Approx. 320     500 440 95gm
Selection Method By Slide Switch on front By Slide Switch on front -
Reset - - Manual
Operating Temperature 0oC to 50oC 0oC to 50oC 0oC to 50oC
       
 
EM 9601
Energy Meter ( kwh) 3Ph-4 W
MM 9601
Multi Meter(V, A, Freq) 3Ph-4 W
VI 5701
Volt meter
AI 5701
Amp. Meter
Supply 230 +/- 20 % Vac (Aux.) 230 +/- 20 % Vac (Aux.) 230 +/- 20 % Vac 230 +/- 20 % Vac
Display Parameter Kwh Volt(P-N),Volt (P-P), Current, Frequency voltage Current
Range 0-9999 kWh Volt- 20-300 VAC ( P-N) Current - 0-999
Amp. Frequency 0-60 Hz
100- 500 V AC 0-20 Amp. (Without
CT.) 0-50,0-100 amp.
(with Use of external CT)
Display 0.4" seven segment display 3 set of 0.4" seven segment display for
voltage,current, frequency resp.
0.56" seven
segment display
0.56" Seven
segment display
Size(mm) 96x96 96x96 38x63 38x63
Cut Out(mm) 92x92 92x92 29x53 29x53
Depth(mm) 110 110 85 85
Weight(Gms) Approx.        
Selection Method Programming of CT ratio through
key pad on front ( External CT
Requires)
Programming through Key Pad.
Programming parameters are CT ratio,
selection of Voltage (P-N) or (P-P) and Phase current
NA NA
Indication NA VRY,
VYB, VBR, VRN, VBN, VYN ,IR, IY, IB
NA NA
Reset By Pressing UP key for
few seconds
NA NA NA
Operating Temperature 0º Degree to 65º Degree 0º Degree to 65º Degree 0º Degree to 65º Degree 0º Degree to 65º Degree
GELCO has recently developed
a new range of micro controller
based panel meters. GELCO
range of Panel meters has
been developed with latest
micro controller based
technology to enhance accuracy
level and functionality. Some
meters are also contrived with
multiple user friendly parameters
such as MM-9601. During
development of this range certain
key parameters like compact size,
user friendly programming has
been taken care.
 
GPM-301
Universal Power Meter 3ph-4 wire
GPM-101
Universal Power Meter ( 1 Ph)
Supply 230 +/- 20 % Vac (Aux.), 50-60 Hz 230 +/- 20 % Vac (Aux.)
Display Parameter Voltage, Current, Frequency, Power(kW),
Active Power (kVa), Reactive Power(kVar),
Energy (kwh),Power factor,
Voltage, Current, Frequency, Power(kW),
Active Power (kVa), Reactive Power(kVar),
Energy (kwh),Power factor, Crest factor, Frequency(Hz)
Range Voltage:20-300Vac (P-N),0-500Vac(P-P),
Current: 0-999.9 Amp, Power(kW): 0-999.9,
Active Power(kVa): 0-999.9, Reactive Power
(kVar) : 0-999.9, Energy : 0-9999, Frequency
: 0-60 Hz, Power Factor - 0 to 1. All parameter
for individual phase and system can be display.
Voltage:20-300Vac (P-N), Current: 0-999.9 Amp,
Power(kW): 0-999.9 ,Active Power(kVa): 0-999.9,
Reactive Power(kVar) : 0-999.9, Energy : 0-9999,
Frequency : 0-60 Hz, Power Factor - 0 to 1.
Display 4 set of 0.4 " seven segment display 4 set of 0.56 " seven segment display
Size(mm) 96x96 96x96
Cut Out(mm) 92x92 92x92
Depth(mm) 110 110
Weight(Gms) Approx.    
Selection Method By Programming Key pads.
external CT is Require. CT ratio can be
programmed by programming key pad
By Programming Key pads.
external CT is Require. CT ratio can be
programmed by programming key pad
Indication Indications for all above parameters
for individual phase and system.
Indications for all above parameters
for individual phase
Reset Reset kwh By Pressing SYSTEM key for few seconds
(kwh)
Reset By Pressing SYSTEM key for few seconds
Operating Temperature 0º Degree to 65º Degree 0º Degree to 65º Degree
       