GELCO automatic Water level controller has been designed to have automatic operation of motor-pump set depending upon the level of liquid in underground as well as overhead tank. When the water reaches below set low level in overhead tank, the unit will switch on the motor pump set automatically. Similarly when the water level reaches to high level in the overhead tank, it will switch off the motor-pump set, provided underground tank is full of water.
If water level falls below set low level in underground tank, it will also switch off the motor pump-set though overhead tank is empty. Thus preventing the motor-pump set from dry running. It is available in different models, namely llc1 & llc2. Model llc1 can be used for three phase motors with dol or fasd starters. While model llc2 can be used for single phase motors upto 2 h.p. & model llc25 can be used for single phase subermisble pumps. Model llc1 measures 140 x 95 x 90 mm & weighs 650 grams approx. While model llc2 & llc25 measures 165 x 165 x 85 mm & weighs 1.6 kg approx. Special magnetic sensors can be used for non conductive liquids.
Four Models Available
LLC1
Suitable for 3_ motors with DOL or FASD starters
LLC2-S
Suitable for 1_ Submersible pump panels.
LLC2
Suitable for 1_ upto 2 H.P. motors.
LLC-001
Suitable for GELCO make electronic motor starter only.
All the above models can be used for single tank or dual tanks.
How To Use
FOR UNDERGROUND TO OVERHEAD TANK To use unit for both tanks, all connection (OH,OL,C,UL,UH) should be used, Whenever liquid level in underground tanks falls below set low level. it swithches off the pump-set, Pumping will restart only when liquid level reaches to set high level ot above that only if demanded by overhead tank. Low level in underground tank to be set above foot-valve to avoid dry running of pump-set. Now motor operation will be as per level in overhead tank.
FOR OVERHEAD TANK To use unit for controlling levels in overhead tank, short points C, UL & UH. Now whenever level in overhead tank falls below set low level, unit operates pump-set automatically and when liquid level reaches to high level, it stops motor pump-set, Motor will reastart only when liquid level falls below low level.
FOR UNDERGROUND TANK To use the unit for underground tank, keep terminals OH & OL open, Now when liquid level falls below set low level, the unit switches off the pump-set & it will switch on the pump-set only when liquid level reaches to high level.
Salient Features
No man power required to operate as fully automatic.
Avoid overflow & dry running.
Longer life, no mechanical system.
Technical Specification
System Voltage
:
LLC1/
:
415V / 110V / 230V +/- 20%, 50Hz,
:
LLC2/LLC2-S
:
230V +/- 20%, 50Hz
Contact Rating
:
LLC1
:
1A at 415V AC,at Pf0.5
:
LLC2-S
:
20A at 230V AC(Resi.)
:
LLC2
:
30A at 230V AC(Resi.)
Sensing Element
:
For all models
:
Stainless Steel Sensors or Magnetic Sensors for non-conductive liquid.
Terminal
:
LLC1
:
Nylon modulded
:
LLC2/LLC2-S
:
Bakelite modulded
:
LLC-001
:
Plug in type
Reset
:
For all models
:
Auto & Manual (For water levels)
Dimensions Overall
:
LLC1
:
140x95x90mm
:
LLc2
:
170x140x70mm
:
LLC2-S
:
165x165x85mm
Mounting
:
LLC1
:
128x74mm
:
LLC2-S
:
158x118mm
Cables for Probes
:
For all models
:
3 core 16/20 size
Weight
:
LLC1
:
650 gms,(approx,)
:
LLC2
:
760 gms,(approx,)
:
LLC2-S
:
1.5 kg.(approx,)
:
LLC-001
:
150 gms,(approx,)
Maximum cable length
:
For all models
:
200 meters
Indication
:
Low/High level indication for Overhead & Underground Tanks, Pump on indication for all models